UC NF Series model example:
Model:
UC NF-90-400/34
UC
UltraClean abbreviation
NF
NF:Nanofiltration membrane
90
Molecular retention:90 / 150 / 280 / 500
400
440:440ft² / 82:82ft²
34
34mil inlet runner (when not marked28mil)
UltraClean nanofiltration membrane has four molecular weight cut-off products of 90, 150, 280, and 500, which can meet the processing needs of different selective separations.It can selectively separate certain salts or organic substances under relatively low operating pressure, providing high-quality products for pure water and fine chemical industries. UltraClean nanofiltration membrane elements are available in two specifications of 8 inches and 4 inches. The products are used in the concentration and purification of food and beverages, and nearly zero discharge of wastewater from municipal engineering.Processing and separation, refining and concentration of petroleum, chemical, biopharmaceutical and other fields.
Product Description:
UltraClean UC NF90 series nanofiltration membrane elements can achieve a high yield of water and at the same time have excellent performance of removal of primary and secondary salts, high removal rate of organic compounds, such as pesticides, herbicides and THM precursor, etc., with high removal ability of natural organic compounds.In the process of water treatment, it can not only reduce the hardness of water, but also effectively remove the toxic and harmful substances in the water, removing turbidity, chroma and organic matter.In addition, the economic value of high-priced salts and small molecules of organic matter can be recovered.It needs low net driving pressure, and can effectively remove impurities or recover useful substances under very low operating pressure. The system runs with low energy consumption and good economy.Suitable for paper printing and dyeing industry and municipal water treatment system.
Product Features:
· Excellent removal performance of primary and secondary salt · Suitable for removing TOC and THM precursors · A system with low operating energy consumption and salt removal under ultra-low pressure
Film size:
Membrane type | Size A inch (mm) | Size B inch (mm) | Size C inch (mm) | Size D inch (mm) | ||||||||||||||||||||||||||||
UC NF-90-400/28 | 40(1,016) | / | 1.125(29) | 7.9(201) | ||||||||||||||||||||||||||||
UC NF-90-78/28 | 37.9(963) | 1.05(26.7) | 0.75(19) | 3.9(99) |
Product Description:
UltraClean UC NF150 series nanofiltration membrane components are prepared using a unique formula and process, which is specially developed for special solute concentration and separation process, with stable and reliable performance and strong pollution resistance.It fills the gap of molecular weight retained by nanofiltration membrane.Suitable for fine material separation, at the same time to remove TOC and THM precursor, monovalent ion salt separation, decolorization, small molecule organic matter separation and concentration, etc.
Product Features:
· Fill the gaps in the molecular weight retained by the existing nanofiltration membrane · Suitable for the separation of fine materials, separation and decolorization of small molecules of organic matter, and salt separation of monovalent and polyvalent ions · Stable chemical performance and strong pollution resistance
Film size:
Membrane type | Size A inch (mm) | Size B inch (mm) | Size C inch (mm) | Size D inch (mm) | ||||||||||||||||||||||||||||
UC NF-150-400/34 | 40(1,016) | / | 1.125(29) | 7.9(201) | ||||||||||||||||||||||||||||
UC NF-150-78/28 | 37.9(963) | 1.05(26.7) | 0.75(19) | 3.9(99) |
Product Description:
UltraClean UC NF280 series nanofiltration membrane elements have ultra-high flux and are capable of highly removing TOC and THM (trihalides) predrives with moderate to moderate divalent salts passing through and other salts passing through to moderate or higher degrees.It is an ideal membrane element for removing organic matter from surface water and groundwater, softening it moderately, concentrating, separating or purifying inorganic salts, organic matter, natural drugs and fermentation broth.Nf280-400/34 elements have a large membrane area and high water yield, providing a wide range of water treatment and concentration and separation applications for industrial production.Suitable for removal of TOC, THM precursors, salt and low operating energy consumption systems under ultra-low pressure, as well as for material separation, municipal and industrial water treatment.
Product Features:
· Ultra-high flux · High removal of TOC and THM (trihalocarbon) precursors · Ultra-low operating pressure can effectively reduce the operating energy consumption of the membrane system
Film size:
Membrane type | Size A inch (mm) | Size B inch (mm) | Size C inch (mm) | Size D inch (mm) | ||||||||||||||||||||||||||||
UC NF-280-400/34 | 40(1,016) | / | 1.125(29) | 7.9(201) | ||||||||||||||||||||||||||||
UC NF-280-78/28 | 37.9(963) | 1.05(26.7) | 0.75(19) | 3.9(99) |
Product Description:
UltraClean UC NF500 series nanofiltration membrane elements are characterized by extremely high flux and high desalination rate, high interception of divalent ions and good passability of monovalent ions, medium removal performance while high yield of water, effective interception of organic compounds with molecular weight above 300~500D, and excellent decolorization performance.The component USES the latest component manufacturing technology to minimize filter dead spots and bypasses.Suitable for reclaimed water, municipal water, etc.There are 4 "and 8" in two different sizes.
Product Features:
· Features extremely high flux and high removal rate · Excellent decolorization performance · Achieve high water yield with moderate removal performance
Film size:
Membrane type | Size A inch (mm) | Size B inch (mm) | Size C inch (mm) | Size D inch (mm) | ||||||||||||||||||||||||||||
UC NF-500-400/28 | 40(1,016) | / | 1.125(29) | 7.9(201) | ||||||||||||||||||||||||||||
UC NF-500-78/28 | 37.9(963) | 1.05(26.7) | 0.75(19) | 3.9(99) |
Film performance parameters:
Membrane type | Effective area ft (m²) | Average water GPD (m3/d) | Stable SWD (%) | |||||||||||||||||||||||||||||
UC NF-90-400/28 | 400(37) | 7,500(28.4) | 85-95 | |||||||||||||||||||||||||||||
9,500(36.0) | ≥ 98 | |||||||||||||||||||||||||||||||
UC NF-90-78/28 | 78(7.2) | 1,400 (5.3) | 85-95 | |||||||||||||||||||||||||||||
1,850 (7.0) | ≥ 98 | |||||||||||||||||||||||||||||||
UC NF-150-400/28 | 400(37) | 8,250 (31.2) | 40-60 | |||||||||||||||||||||||||||||
9,780 (36.8) | ≥ 98 | |||||||||||||||||||||||||||||||
UC NF-150-78/28 | 78(7.2) | 1,610(6.1) | 40-60 | |||||||||||||||||||||||||||||
1,910(7.2) | ≥ 98 | |||||||||||||||||||||||||||||||
UC NF-280-400/28 | 400(37) | 14,700 (55.6) | 40-60 | |||||||||||||||||||||||||||||
12,500 (47.3) | ≥ 98 | |||||||||||||||||||||||||||||||
UC NF-280-78/28 | 78(7.2) | 2,925(11.1) | 40-60 | |||||||||||||||||||||||||||||
2,500 (9.4) | ≥ 97 | |||||||||||||||||||||||||||||||
UC NF-500-400/28 | 400(37) | 13,200(50.0) | ≥ 90 | |||||||||||||||||||||||||||||
UC NF-500-78/28 | 78(7.2) | 2,700(10.2) | ≥ 90 |